Skip to content

RCC · Buildings and IoT

Fire events in the security picture, with life safety in charge

Fire panels supervised, alarms acknowledged with a reason, public address and emergency lighting, and an evacuation workflow that opens the right cameras, while the life-safety system keeps control.

A fire panel event becomes a guided evacuation, without RCC taking control of the panelFour stages run left to right: the fire panel, monitored only, the event in RCC, the camera opened for the zone, and the evacuation workflow. Below, three outcomes: acknowledged with a reason, evacuation started, or an impairment logged.fire panelmonitored onlyeventzone 12cameraopens for the zoneevacuationworkflow · PAacknowledged with reasonevacuation startedimpairment logged
  1. Fire panels are supervised, never controlled: RCC monitors, the panel decides.
  2. A fire event opens the zone’s camera and asks a life-safety operator to acknowledge with a reason.
  3. The evacuation workflow drives public address and emergency lighting, and the incident records every step.

Capabilities

What fire and life safety in RCC does

  • Panel supervision

    Fire panels from EST, Simplex, Notifier, Siemens and others, through BACnet gateways and SIA DC-09.

  • Acknowledge with a reason

    Life-safety operators acknowledge alarms with a reason, recorded in the audit trail.

  • Public address

    Paging zones through Bosch PRAESENSA, Axis audio and SIP paging.

  • Emergency lighting

    Lighting and fire pump status over BACnet and Modbus.

  • Impairments

    Isolations and impairments tracked until they are restored.

  • Evacuation workflow

    Camera pop-up, mustering and evacuation steps, started from the event.

How it works

From panel to evacuation

  1. Connect panels

    Monitor-only connectors.

  2. Map zones

    Zones linked to cameras and areas.

  3. Respond

    Acknowledge, verify, evacuate.

  4. Report

    Every event and impairment recorded.

Where it is used

Where fire events meet security

  • Hospitals

    Phased evacuation with clear roles.

  • Industrial sites

    Fire and gas events with mustering.

  • Campuses

    Building-by-building response.

On the RCC platform

Stronger next to the rest of RCC

A fire alarm opens the cameras in its zone and starts the evacuation workflow and mustering, while the fire panel stays in charge of life safety.

Questions

What buyers ask

Can RCC silence or reset a fire panel?

No. Fire connectors only monitor. The life-safety system stays in control.

Check your fire panels

Send us your fire panel makes and gateways. We will show which RCC supervises on day one, and an evacuation workflow on your site plan.